Independent UK estimate
Plug-In Solar Savings Calculator
See what a small solar system might generate, save and repay. Add a few details about your home and we’ll estimate the result using regional solar data from the European Commission’s PVGIS service and a transparent daytime-use model.
1. Your System & Home
Adjust every assumption to suit your home.
Your Results
Annual estimate, with export income set to £0.
Estimated monthly solar generation
Regional monthly profile, adjusted for your system
What this means for you
What if?
These change the inputs above. The cheaper-kit option uses a fresh, verified, in-stock delivered offer where available; mounting and installation costs may be extra.
The link includes your assumptions and broad region, never your postcode or coordinates. A location-based result reopens as a regional estimate.
How changes affect your annual saving
Size and daytime-use comparisons keep the other settings. Direction comparisons use the regional approximation; select a direction and rerun the location lookup for a local model.
System size
Orientation
Daytime use
Systems to compare for this scenario
Closest panel capacities among our researched, currently verified kits with fresh retailer offers. Check mounting, space and electrical suitability separately.
How plug-in solar savings work
Solar electricity is valuable when it replaces electricity you would otherwise buy. Your appliances use available solar first and the grid supplies the rest. Surplus may be exported, but this calculator values export at £0 because an export tariff is not automatic.
New to the format? Start with PluginSol’s beginner’s guide and Plug-In Solar UK FAQ.
Why 800W does not mean 800W all day
Watts describe rated power under standard test conditions. Real output rises and falls with daylight, cloud, temperature, direction and inverter limits. Annual energy is measured in kilowatt-hours, and that drives the saving. Our 800W generation guide explains the difference.
Location, direction, angle and shade
Southern and eastern regions generally receive more annual solar energy, although a good northern installation can beat a shaded southern one. South-facing panels at a useful tilt tend to maximise annual output. East- or west-facing panels make less overall but spread it earlier or later in the day.
A vertical balcony panel sacrifices annual generation, especially in summer. Flat panels lose some useful angle. Shade is less polite: a railing, chimney, fence or tree can cut output, so choose that setting honestly.
Why daytime electricity use is crucial
A solar-only system cannot save a kilowatt-hour nobody uses. Fridges, routers, computers and daytime cooking can absorb generation. A home empty on weekdays will normally export more and save less. Low, Medium and High use the MCS domestic occupancy archetypes, not one blanket percentage. Entered annual household consumption selects the matching MCS demand band; otherwise the calculator uses the estimated 3,500–3,999kWh band.
See our realistic savings and payback guide for worked examples.
Seasonal variation and realistic payback
May, June and July typically do much more work than December, so the chart uses PVGIS monthly data rather than dividing by twelve. Simple payback divides today’s editable system cost by first-year saving. It excludes finance, maintenance, degradation and future tariff changes.
Before fitting anything, read the installation guide and G98/DNO guide. The EcoFlow versus UKSOL comparison separates hardware value from the exact GB connection route.
Why this remains an estimate
PVGIS describes long-term typical conditions at one representative point per region. It cannot see your tree, balcony above, local horizon, dirty panel, inverter behaviour or changing routine. By default a postcode selects a broad region locally. The optional location lookup sends it to Postcodes.io only when requested, then uses rounded coordinates for a PVGIS model. Neither mode is a roof survey or a prediction of this year’s weather.
Method, assumptions and sources
Optional location model: PVGIS 5.3, crystalline silicon, free-standing panels, 14% system losses, modelled terrain horizon, selected direction and tilt. Coordinates are rounded to two decimal places before calculation. Cached models are retained for 30 days; the exact postcode is never stored by PluginSol. Local obstacles and inverter clipping are not modelled. Above 800Wp of panels, an 800VA inverter can reduce output below this estimate.
Generation in regional mode: locally stored PVGIS 5.3 monthly AC output for representative regional coordinates, crystalline-silicon PV, south-facing 35° tilt and 14% system losses. Generation = regional kWh/kWp × system kWp × orientation × angle × shading.
Orientation: South 1.000; SE/SW 0.882; E/W 0.801; NE/NW 0.631; North 0.547. Angle: optimal 1.000; shallow 0.936; vertical 0.730; flat 0.836. Ratios are validated PVGIS runs at the North West reference point. Shading: none 1.00; light 0.90; moderate 0.75; heavy 0.55—broad site allowances, not PVGIS outputs.
Self-consumption: MCS MGD 003 Issue 2.0 PV-only lookup tables. Entered annual use selects its 500kWh demand band from 1,500–5,999kWh; “I don’t know” selects the estimated 3,500–3,999kWh band. Low = out all day; Medium = in half the day; High = home all day. Calculated solar generation selects the corresponding 300kWh generation row.
Money/carbon: saving = generation × self-consumption × import price. Payback = cost ÷ saving. Default price 26.32p/kWh, Ofgem GB direct-debit average, 1 October–31 December 2026. Standing charges are unchanged. No export income, battery, maintenance or future tariff changes are included.
Sources: PVGIS 5 manual; MCS MGD 003; Ofgem unit rates; 2026 conversion factors.
Important: Indicative first-year estimate, not a guarantee. Export income is £0. Check mounting, electrical suitability, product instructions and current GB requirements before buying or connecting.